Vehicles and chargers are rough on electronics: constant vibration, cold starts and 400 V and more on the bus. Albright HV500 is a sealed, single-pole DC contactor for 12 to 1000 V and up to 500 A thermal rating, and its data sheet reads like it was written for that environment.
Run it yourself
Choose a coil and an auxiliary switch, then power the coil up and down. The contactor, the meters and the cut-away react to every move. Switch on 'Main contact sticks' and watch what the mirror contact does about it.
Coil power
Load power (example values you set)
AUX wires, step by step:
Coil options and auxiliary switch, explained straight
PWM coil economiser
Closing a contactor takes a hard push. Keeping it closed takes almost nothing. The PWM economiser board is fitted at the Albright factory and handles that difference for you.
- Pull-in. The coil receives 27 W and the contacts are shut in less than 20 ms.
- Holding. The board chops the coil supply at high speed. The coil then averages 3 W, roughly one ninth of the pull-in figure.
- Release. Cut the supply and the contacts are open in less than 5 ms. With the PWM board on board, back EMF is 0 V and the coil is suppressed.
What you gain: a cooler coil and a lighter load on your supply. Coil voltages run from 12 to 96 V DC, and swapping the red and black leads by mistake does no harm because the board is reverse-polarity protected.
Watch out: give it clean, smooth DC. A ramping supply voltage is not compatible with the PWM board. The hermetic seal covers the PWM circuit as well.
Magnetic latching
A permanent magnet in the coil assembly keeps the contacts where you left them. You only use the coil when you want to change state.
- Close. Give it a pulse of roughly 500 ms, plus to the red lead and minus to the black lead. The coil takes 12 W for the duration.
- Hold. You do nothing. It stays closed at zero watts.
- Open. Reverse the polarity for 200 to 500 ms: minus to red, plus to black.
What you gain: no coil power at all while nothing moves. Ideal for packs that stay connected for long stretches, or where coil heat is a problem.
Watch out: a latching contactor is not failsafe. If control power fails it stays put and does not open on its own, so plan your system around that.
Intermittent duty
The intermittent (INT) coil is made for switching on load, or for builders who run their own PWM circuit.
- Run your own PWM at 10 kHz or above. Albright's best results come at 15 to 20 kHz.
- Short-duty jobs such as pump control: ask Albright Technical.
Unsure which coil fits? Describe your application and we get Albright's view.
Mirror contact: proof, not a guess
The risk: turning the coil off is only an order. It does not show that the main contacts really opened. If they stick together after hard switching, the pack stays connected while your system believes it is off.
The fix: order the auxiliary switch as normally open (white wires), normally closed (blue wires) or mirror, NC (orange wires). The mirror contact is tied to the main contacts and is closed only while they are open. Your controller therefore gets evidence that the load is cut off. Test it in the demo above: pick Mirror, switch on 'Main contact sticks (fault)' and cycle the coil.
Albright describes the mirror contact as a failsafe status signal for the main contacts, in normal running and in a fault, and refers to EN 60947-4-1 Annex F and EN 60947-5-1 Annex L. The demo illustrates the principle. The normally open and normally closed options are drawn here as following the contactor operation; ask us how they behave in your design. Auxiliary switch rating: 1 A at 24 V DC resistive, minimum 100 mA at 12 V.
The numbers that matter in a vehicle or charger
Shake it
20 G peak shock and 80 to 2000 Hz sinusoidal vibration at 20 G peak, as stated by Albright. Put them next to the figures of the contactor you use today.
Freeze it, heat it
−45 °C to +85 °C operating, and higher with current derating. Storage up to +120 °C.
One family up to 1000 V
12 V to 1000 V DC rated contact voltage, so the same contactor family covers small packs and big chargers.
Both directions
No polarity on the main contacts. Try the braking switch in the demo and watch current flow back to the battery.
Specifications at a glance
| Rated contact voltage | 12 V – 1000 V DC |
|---|---|
| Current | 250 A continuous with 50 mm² (1-1/0 AWG) cables; up to 500 A with 190 mm² (350 MCM) busbars |
| Coil voltages | 12, 24, 36, 48, 60, 72, 84, 96 V DC |
| Operating temperature | −45 °C to +85 °C (higher possible with current derating) |
| Shock and vibration | 20 G peak shock; 80–2000 Hz sinusoidal vibration, 20 G peak |
| Mechanical life | Main contacts over 10⁶ cycles |
| Insulation and dielectric | Over 200 MΩ; 4000 V DC withstand, leakage under 1 mA |
| Weight | Switch 400 g, bracket 20 g |
| Mounting | Rotatable bracket with six angles |
| Recognition | UL Recognised (product status is shown on Albright's website) |
Typical jobs
Albright names vehicles and charging among the typical jobs for the HV series. Confirm the standards and approvals your project needs; we ask Albright about product status for you.
Engineering notes from Albright
Capacitive loads
Capacitors in your circuit? Then you need pre-charging.
Latching is not failsafe
With a magnetic latching coil the contacts stay in their last state when power is gone. Design for it.
Smooth DC for PWM
The PWM board expects steady DC. It does not work from a ramped supply voltage.
Verify in your application
Treat the data as a guide. Some derating may apply, so Albright advises proving the performance in your own application.
Send the vehicle or charger specification
Give us voltage, continuous and peak current, coil voltage and switching rate and we propose the HV500 configuration. Several units for a series? Ask for a quote. One for the prototype? Order it right now.
Quick answers
Does it count as a safety device?
No. It is a contactor for switching DC loads. Safety functions and the safety design remain with the equipment designer.
Can it open and close with load on?
Yes, inside Albright's make and break current limits. Silver alloy tips are an option when you switch under load often. Check the figures for your voltage and current.
Which coil is right for me?
PWM economiser: low holding power. Magnetic latching: zero holding power. Intermittent: you bring the PWM. Tell us the application and we make the call with you.
Is it serviceable?
No. The hermetic seal means HV contactors cannot be serviced.
Does it have automotive approval?
Albright states UL Recognised and points to its website for product status. We do not claim anything beyond that. Tell us what your project requires and we ask Albright.